Background

 

Heat Shrink Insulation Connectors

Download Brochure of Heat Shrink Insulation Connectors

Adhesive-Lined Insulating Caps

Download Brochure of SBRS- CAPS
Adhesive-Lined Insulating Caps

Adhesive lined, heat shrink insulating caps specifically designed to insulate, seal and protect end or stub splices in wiring harness and electronic assemblies.


Features
  • 4:1 shrink ratio allows fewer sizes to cover a wide range of profiles
  • Seals and protects against water, moisture and chemical
  • Adhesive bonds readily to PVC, XLPE and PP-EPDM cable jackets
  • Shrinks rapidly for quick installation
  • Continuous operating temperature:-45℃-125℃
  • Minimum shrinking temperature: 125℃

Code

Size (mm)

Standard Length(mm)

Expanded

 

Recoverd

 

Internal Diameter Min(mm)

Internal Diameter Max(mm)

Outer Layer Thickness (mm)

Adhesive Thickness (mm)

Total Wall Thickness (mm)

CAPS-1

3.2

22

5.72

≤1.27

0.64

0.56

1.20

CAPS-2

4.8

25.4

7.44

≤1.65

0.76

0.76

1.52

CAPS-3

6.4

28.4

10.85

≤2.41

0.89

1.37

1.91

Property

Test Method

Standard

Typical Performance

Tensile Strengtn(MPa)

ASTM D2671

≥10.4

11.5

Elongation(%)

ASTM D2671

≥300

450

Tensile Strengtn after aging (MPa)

UL224 158X168hr

≥7.3

8.5

Elongation after aging(%)

Ul224 158X168hr

≥200

350

Dieletric strength(kV/mm)

IEC 60243

≥15

17.5

Volume resistivity(Ω.cm)

IEC 60093

≥1X101 4

2.5X101 4

Semi-rigid, Adhesive-Lined Insulating Caps

Download Brochure of SBRS- CAPS NF
Semi-rigid, Adhesive-Lined Insulating Caps

Semi-rigid, adhesive lined, heat shrink insulating caps specifically designed to insulate, seal and protect end or stub splices under extreme operating conditions


Features
  • 4:1 shrink ratio allows fewer sizes to cover a wide range of profiles
  • Seals and protects against water, moisture and chemical
  • Adhesive bonds readily to PVC, XLPE and PP-EPDM cable jackets
  • Shrinks rapidly for quick installation
  • Continuous operating temperature:-45℃-125℃
  • Fully shrink temperature: 125℃
  • Not flame-retardant

Code

Size (mm)

Standard Length (mm)

Expanded

Recoverd

Internal Thickness Min(mm)

Internal Diameter Man(mm)

Outer Layer Thickness (mm)

Adhesive Thickness (mm)

Total Wall Thickness (mm)

CAPS NF-1

3.2

22

3.2

0.80

0.64

0.56

1.20

CAPS NF-2

4.8

25.4

4.8

1.30

0.76

0.76

1.52

CAPS NF-3

6.4

28.4

6.4

1.52

1.00

0.91

19.10

CAPS NF-4

9.5

31.8

9.5

2.00

1.08

1.00

2.08

CAPS NF-5

12.7

38.1

12.7

2.41

1.30

1.24

2.54

Property

Test Method

Standard

Typical Performance

Tensile Strengtn(MPa)

ASTM D2671

≥10.4

11.5

Elongation(%)

ASTM D2671

≥300

450

Tensile Strengtn after aging (MPa)

UL224 158X168hr

≥7.3

8.5

Elongation after aging(%)

UL224 158X168hr

≥200

350

Dieletric strength(kV/mm)

IEC 60243

≥15

17.5

Volume resistivity(Ω.cm)

IEC 60093

≥1X101 4

2.5X101 4

Heat Shrink Insulation Connectors

Download Brochure of SBRS- DZ
Heat Shrink Insulation Connectors

Crystal clear, semi-rigid, adhesive lined tubing with integral solderless splice connector


Features
  • Exceptional clarity for visual confirmation of seal
  • Seal& protects against water, corrosive compounds, moisture& contaminants
  • Tough, durable heat shrink tubing resists abrasion, crimp tool damage& splitting
  • Shrinks 40% faster than nylon, preventing.
  • Inner adhesive bonds to plastics, rubbers & metals
  • Meets& conforms to OEM wiring specifications for installation& repairs
  • Continuous operating temperature:-45℃-125℃
  • Minimum shrinking temperature: 80℃

Code

Size

Tube Diameter

Color

Standard Package

AWG

mm2

Expanded Min(mm)

Recovered Max(mm)

Length (mm)

SBRS-DZ-1

22-18

0.5-1.0

4.8

1.2

35.0

red

1000pc/bag

SBRS-DZ-2

16-14

1.5-2.5

5.5

1.4

35.0

blue

1000pc/bag

SBRS-DZ-3

12-10

4.0-6.0

6.5

1.5

42.0

yellow

500pc/bag

Property

Test Method

Standard

Typical Performance

Tensile Strengtn(MPa)

ASTM D2671

≥14

16

Elongation(%)

ASTM D2671

 300

450

Tensile Strengtn after aging (MPa)

UL224 158X168hr

≥7.3

15

Elongation after aging(%)

Ul224 158X168hr

≥200

350

Dieletric strength(kV/mm)

IEC 60243

≥15

17.5

Volume resistivity(Ω.cm)

IEC 60093

≥1X101 4

2.5X101 4

Property

Test Method

Standard

Water Absorption

ASTM D570

0.5%

Sofening Point()

ASTM E28

95±5

Strength of pearing(PE)

ASTM D 1000

120N/25mm

Strength of pearing(AL)

ASTM D 1000

80N/25mm

Semi-rigid, Adhesive-Lined Insulating Caps

Download Brochure of SBRS-CAPS-RL
Semi-rigid, Adhesive-Lined Insulating Caps

Heat shrink end caps are a simple yet effective method for sealing cable ends, pipe, conduit or other similar objects. Typical Applications Watertight sealing of cable ends and pipe conduit Standards Rated for 600/1000V


Features
  • 3:1 shrink ratio
  • Resistant to common fluids and solvents
  • Superior resistance to weathering ,moisture contamination and adverse environmental conditions
  • Standard adhesive liner provides complete environmental protection and insulation
  • Heat indicating lines
  • Resistant to common fluids and solvents
  • Coated hot melt adhesive resists pull-off
  • Fully shrink temperature :125℃
  • Continuous operating temperature: -55℃ to 110℃

Expanded Length (Nom)

Expanded

Recoverd

General Use Diameter

Cable Range

InternalDiameter Min

InternalDiameter Max-d

Wall Thickness Nom-W

mm

IN

mm

IN

mm

IN

mm

IN

mm

IN

AWG/MCM

50.80

2.00

10.20

0.40

3.80

0.15

2.00

0.080

4.5-8.5

0.18-0.34

#8-#1

63.50

2.50

19.10

0.75

5.60

0.22

2.00

0.080

6-16.5

0.24-0.65

#2-4/0

76.20

3.00

27.90

1.10

10.20

0.40

2.40

0.095

11.5-25

0.45-1

2/0-500

76.20

3.00

33.00

1.30

10.20

0.40

2.40

0.095

11.5-30

0.45-1.2

300-1000

88.90

3.50

38.10

1.50

12.70

0.50

2.40

0.095

14-35

0.55-1.4

500-1500

88.90

3.50

43.20

1.70

12.70

0.50

2.50

0.100

14-40

0.55-1.6

650-1750

88.90

3.50

52.10

2.05

19.00

0.75

2.50

0.100

21-45

0.82-1.8

900-2500

101.60

4.00

69.80

2.75

25.40

1.00

2.50

0.100

30-63

1.2-2.5

2000-2500

114.30

4.50

88.90

3.50

30.00

1.18

2.50

0.100

33-83.8

1.3-3.3

--

139.70

5.50

119.40

4.70

39.90

1.57

2.70

0.105

40.6-114.3

1.6-4.5

--

Property

Test Method

Standard

Typical Performance

Tensile Strengtn(MPa)

ASTM D2671

≥10.4

11.5

Elongation(%)

ASTM D2671

≥300

450

Tensile Strengtn after aging (MPa)

UL224 158 X168hr

≥7.3

8.5

Elongation after aging(%)

UL224 158 X168hr

≥200

350

Dieletric strength(kV/mm)

IEC 60243

≥15

17.5

Volume resistivity(Ω.cm)

IEC 60093

≥1X101 4

2.5X101 4

Property

Test Method

Standard

Water Absorption

ASTM D570

0.2%

Sofening Point()

ASTM E28

90±5

Strength of pearing(PE)

ASTM D 1000

120N/25mm

Strength of pearing(AL)

ASTM D 1000

80N/25mm